Oral solids · Contract manufacturing enquiry

Ondansetron 4 mg Uncoated · Tablets

Request manufacturing feasibility

Discuss third-party manufacturing with Walter Healthcare, India. Confirm the formulation, tablet presentation, packaging and project requirements for a product-specific quotation.

Catalogue reference
WH-1140
Composition and strength
Ondansetron 4 mg Uncoated
Dosage form
Tablets
Indicative administration route
Oral
Therapeutic navigation area
Gastroenterology & hepatology
Pharmacological class
Antiemetic
Manufacturing stream
Non-beta-lactam
BCS class
Class I

Catalogue details support an initial B2B discussion. Walter confirms the applicable unit, current licence scope, formula, target market and commercial feasibility before making a commitment.

Clinical reference

Mechanism and pharmacokinetics.

Explore the published evidence for the ingredients in Ondansetron 4 mg Uncoated Tablets. Each reference identifies its source formulation and study context. Ingredient studies describe the named reference product; they do not establish the pharmacokinetics, clinical suitability or bioequivalence of this finished formulation.

How to read our product information and sources ↗

Prescribing-label excerpts

Ondansetron Hydrochloride

Reference for: Ondansetron. Source presentation: tablet, film coated. Source route: oral.

Mechanism of action

Ondansetron is a selective 5-HT 3receptor antagonist. While its mechanism of action has not been fully characterized, ondansetron is not a dopamine-receptor antagonist. Serotonin receptors of the 5-HT 3type are present both peripherally on vagal nerve terminals and centrally in the chemoreceptor trigger zone of the area postrema. It is not certain whether ondansetron’s antiemetic action is mediated centrally, peripherally, or in both sites. However, cytotoxic chemotherapy appears to be associated with release of serotonin from the enterochromaffin cells of the small intestine. In humans, urinary 5-hydroxyindoleacetic acid (5-HIAA) excretion increases after cisplatin administration in parallel with the onset of emesis. The released serotonin may stimulate the vagal afferents through the 5-HT 3receptors and initiate the vomiting reflex.

Pharmacokinetics

Absorption — Ondansetron is absorbed from the gastrointestinal tract and undergoes some first-pass metabolism. Mean bioavailability in healthy subjects, following administration of a single 8 mg tablet, is approximately 56%.

Ondansetron systemic exposure does not increase proportionately to dose. The area under curve (AUC) from a 16 mg tablet was 24% greater than predicted from an 8 mg tablet dose. This may reflect some reduction of first-pass metabolism at higher oral doses.

Food Effects:Bioavailability is also slightly enhanced by the presence of food.

Distribution — Plasma protein binding of ondansetron as measured in vitrowas 70% to 76% over the concentration range of 10 to 500 ng/mL. Circulating drug also distributes into erythrocytes.

Elimination — Metabolism and Excretion: Ondansetron is extensively metabolized in humans, with approximately 5% of a radiolabeled dose recovered as the parent compound from the urine. The metabolites are observed in the urine. The primary metabolic pathway is hydroxylation on the indole ring followed by subsequent glucuronide or sulfate conjugation.

In vitro metabolism studies have shown that ondansetron is a substrate for human hepatic cytochrome P-450 enzymes, including CYP1A2, CYP2D6, and CYP3A4. In terms of overall ondansetron turnover, CYP3A4 played the predominant role. Because of the multiplicity of metabolic enzymes capable of metabolizing ondansetron, it is likely that inhibition or loss of one enzyme (e.g., CYP2D6 genetic deficiency) will be compensated by others and may result in little change in overall rates of ondansetron elimination.

Although some nonconjugated metabolites have pharmacologic activity, these are not found in plasma at concentrations likely to significantly contribute to the biological activity of ondansetron.

Specific Populations — Age: Geriatric Population:A reduction in clearance and increase in elimination half-life are seen in patients older than 75 years compared to younger subjects [see Use in Specific Populations (8.5)] .

Sex:Gender differences were shown in the disposition of ondansetron given as a single dose. The extent and rate of absorption are greater in women than men. Slower clearance in women, a smaller apparent volume of distribution (adjusted for weight), and higher absolute bioavailability resulted in higher plasma ondansetron concentrations. These higher plasma concentrations may in part be explained by differences in body weight between men and women. It is not known whether these sex-related differences were clinically important. More detailed pharmacokinetic information is contained in Tables 5 and 6.

Renal Impairment:Renal impairment is not expected to significantly influence the total clearance of ondansetron as renal clearance represents only 5% of the overall clearance. However, the mean plasma clearance of ondansetron was reduced by about 50% in patients with severe renal impairment (creatinine clearance less than 30 mL/min). The reduction in clearance was variable and not consistent with an increase in half-life [see Use in Specific Populations (8.7)] .

Hepatic Impairment:In patients with mild-to-moderate hepatic impairment, clearance is reduced 2-fold and mean half-life is increased to 11.6 hours compared with 5.7 hours in healthy subjects. In patients with severe hepatic impairment (Child-Pugh score of 10 or greater), clearance is reduced 2-fold to 3-fold and apparent volume of distribution is increased with a resultant increase in half-life to 20 hours [see Dosage and Administration (2.2), Use in Specific Populations (8.6)] .

Drug Interaction Studies — CYP 3A4 Inducers: Ondansetron elimination may be affected by cytochrome P-450 inducers. In a pharmacokinetic trial of 16 epileptic patients maintained chronically on CYP3A4 inducers, carbamazepine, or phenytoin, a reduction in AUC, C max, and t ½of ondansetron was observed. This resulted in a significant increase in the clearance of ondansetron. However, this increase is not thought to be clinically relevant [see Drug Interactions (7.2)] .

Chemotherapeutic Agents: Carmustine, etoposide, and cisplatin do not affect the pharmacokinetics of ondansetron [see Drug Interactions (7.4)] .

Antacids: Concomitant administration of antacids does not alter the absorption of ondansetron.

Selected passages from the cited U.S. prescribing label. The studies concern the source product and populations named in each passage; they do not establish Walter-product bioequivalence, an approved indication, or the kinetics of another fixed combination. Tables and the full prescribing information remain available in the source.

Source: DailyMed: Ondansetron Hydrochloride — tablet, film coated

Reference accessed . Label revision: 2026-09-01.

Manufacturing & packaging brief

Plan the tablet presentation.

Use this preparation guide for Ondansetron 4 mg Uncoated Tablets. These are the decisions to resolve with the technical team before a site, process and commercial scope are confirmed.

Presentation & formulation

Define release type, coating, scoring and any reference-product requirements. Keep each strength and presentation as a separate item in the brief.

Quality & technical transfer

Agree the product specification, analytical methods and applicable dissolution or disintegration requirements. Identify the formula and process information available for transfer.

Review the technical documents

Packaging configuration

Compare the proposed blister, strip or bottle with the formulation and its protection requirements. Specify tablets per primary pack and primary packs per carton.

Explore packaging options

Details to confirm for this record

Exact presentation
Use “Ondansetron 4 mg Uncoated Tablets” consistently in the brief. Specify coating, release, grade or other presentation requirements explicitly where the catalogue does not define them.

Quantities, MOQ & lead time

For Ondansetron 4 mg Uncoated Tablets, state the tablet count and finished-pack count, target market and reorder forecast. MOQ and lead time depend on the assessed formula, process, components, testing and project readiness; request those terms in writing.

Discuss this manufacturing brief

Explore the context

Build the right manufacturing brief.

Common questions

Before you request a quotation.

Ondansetron 4 mg Uncoated Tablets

What is listed in the catalogue?

The catalogue lists Ondansetron 4 mg Uncoated as tablets in its gastroenterology & hepatology navigation area and non-beta-lactam manufacturing stream.

Is manufacturing availability confirmed?

No. Walter checks current facility permissions, formulation and equipment fit, testing, packaging and target-market requirements before written confirmation.

What do I need for a quotation?

Share the exact composition and strength, tablets presentation, target market, initial quantity, preferred pack and timing. Identify whether this is a new product, development brief or transfer.

The quotation must confirm MOQ, inclusions, prerequisites and lead time for the proposed product and site.

Can I change the pack or target market?

Include each proposed pack and country in the enquiry. Container compatibility, artwork, supporting stability evidence, permission scope and destination requirements need review for the requested configuration.

A catalogue record does not establish export registration or a shelf-life commitment.

How do I submit my enquiry?

Use the product-specific enquiry button to carry this composition and dosage form into the form. After a successful submission, a receipt reference confirms that your brief has been saved for review. Use the RFQ checklist to prepare the remaining details.

Technical document review

Which documents can I ask Walter to review?

Ask about manufacturing and packing records, specifications, analytical methods, Certificates of Analysis (COA), stability evidence, the Process Validation Protocol (PVP) and Process Validation Report (PVR). The wider checklist below covers supplier qualification, technical transfer and ongoing supply.

View the full document checklist 14 review areas
Site, licence and audit scope
Manufacturing licence, applicable product permissions, GMP certificates, Site Master File, supplier-qualification questionnaire and relevant audit responses.
Manufacturing, packing and batch release
Master Formula Record (MFR), master packing instructions, Batch Manufacturing Record (BMR), Batch Packing Record (BPR), reconciliation and authorised release records.
Process validation and continued verification
Process Validation Protocol (PVP), Process Validation Report (PVR), process performance qualification documents and continued process verification trends.
Equipment, facilities and utilities
Validation Master Plan (VMP), user requirements, DQ/IQ/OQ/PQ records, calibration and maintenance evidence for relevant equipment and utilities.
Cleaning, carryover and hold times
Cleaning Validation Protocol (CVP), Cleaning Validation Report (CVR), residue limits, recovery studies and applicable clean, dirty and process hold-time studies.
Specifications and analytical evidence
Specifications, Method of Analysis (MOA), Standard Testing Procedure (STP), Certificates of Analysis (COA), analytical validation, verification and method-transfer records.
Stability, packaging and transport
Stability protocols/reports, ongoing stability commitments, pack specifications, approved artwork, compatibility and applicable packaging or transport studies.
Development and technology transfer
Development report, technology-transfer protocol/report, gap assessment, control strategy, critical quality attributes and critical process parameters.
Quality reviews, investigations and changes
Product Quality Review (PQR) / Annual Product Review (APR), deviations, CAPA, change control, OOS/OOT trends, complaints, recalls and relevant SOP/training records.
Material suppliers and impurity risks
API/excipient supplier qualification, traceability, material COAs, relevant origin declarations and impurity risk assessments with supporting tests.
Sterile-product evidence, where applicable
Contamination Control Strategy (CCS), media-fill/aseptic simulation reports, sterilisation and filtration validation, environmental monitoring, sterility/endotoxin and container-closure integrity evidence.
Computerised systems and data integrity
Computerised-system validation, access controls, audit-trail review, backup/restore checks and relevant data-integrity procedures.
Market-specific regulatory support
Applicable dossier sections, API master-file/CEP support, bioequivalence or biowaiver evidence and Certificate of a Pharmaceutical Product (CPP/CoPP), where required and available.
Quality agreement and access arrangements
Quality/technical agreement covering responsibilities, release, changes, subcontracting, investigations, complaints, recalls, audits and document access.

Agree the list for the exact product, site, process, pack, market and project stage. QA confirms what exists, applies and may be shared; some records may require an NDA, redaction or controlled review. See document definitions and review guidance.

Important qualification

This B2B catalogue record is not proof of current approval or confirmation that Ondansetron 4 mg Uncoated Tablets is available for sale. It is not prescribing information or patient advice. Any Drugs Rules status, current approval, exemption, applicable unit, licence scope, formulation, claims, brand use, destination-market registration and commercial feasibility require documentary verification and Walter's written confirmation. Read the full regulatory disclaimer.

Composition and classification are taken from Walter's product catalogue. The manufacturing guide helps buyers prepare a technical brief. Clinical references, where shown, describe the cited product and study. Manufacturing guide updated .