Oral solids · Contract manufacturing in India

Nicardipine Hcl 40 mg · Hard-gelatin capsules

Request manufacturing feasibility

Discuss third-party manufacturing of Nicardipine Hcl 40 mg Hard-gelatin capsules with Walter Healthcare, India. Share your target market, required capsule count and finished-pack count, packaging and launch timeline for a product-specific quotation.

Catalogue reference
WH-5058
Composition and strength
Nicardipine Hcl 40 mg
Dosage form
Hard-gelatin capsules
Indicative administration route
Oral
Therapeutic navigation area
Cardiovascular
Pharmacological class
Calcium-channel blocker
Manufacturing stream
Non-beta-lactam
BCS class
Class II

Catalogue details support an initial B2B discussion. Walter confirms the applicable unit, current licence scope, formula, target market and commercial feasibility before making a commitment.

Clinical reference

Mechanism and pharmacokinetics.

Explore the published evidence for the ingredients in Nicardipine Hcl 40 mg Hard-gelatin capsules. Each reference identifies its source formulation and study context. Ingredient studies describe the named reference product; they do not establish the pharmacokinetics, clinical suitability or bioequivalence of this finished formulation.

How to read our product information and sources ↗

Prescribing-label excerpts

Nicardipine Hydrochloride

Reference for: Nicardipine Hcl. Source presentation: capsule. Source route: oral.

Mechanism of action

Nicardipine hydrochloride capsules are a calcium entry blocker (slow channel blocker or calcium ion antagonist) that inhibits the transmembrane influx of calcium ions into cardiac muscle and smooth muscle without changing serum calcium concentrations. The contractile processes of cardiac muscle and vascular smooth muscle are dependent upon the movement of extracellular calcium ions into these cells through specific ion channels. The effects of nicardipine hydrochloride capsules are more selective to vascular smooth muscle than cardiac muscle. In animal models, Nicardipine hydrochloride capsules produce relaxation of coronary vascular smooth muscle at drug levels that cause little or no negative inotropic effect.

Pharmacokinetics

Nicardipine hydrochloride capsules are completely absorbed following oral doses administered as capsules. Plasma levels are detectable as early as 20 minutes following an oral dose and maximal plasma levels are observed within 30 minutes to 2 hours (mean T max= 1 hour). While nicardipine hydrochloride capsules are completely absorbed, it is subject to saturable first pass metabolism and the systemic bioavailability is about 35% following a 30-mg oral dose at steady-state.

When nicardipine hydrochloride capsules were administered 1 or 3 hours after a high-fat meal, the mean C maxand mean AUC were lower (20% to 30%) than when nicardipine hydrochloride capsules were given to fasting subjects. These decreases in plasma levels observed following a meal may be significant, but the clinical trials establishing the efficacy and safety of nicardipine hydrochloride capsules were done in patients without regard to the timing of meals. Thus, the results of these trials reflect the effects of meal-induced variability.

The pharmacokinetics of nicardipine hydrochloride capsules are nonlinear due to saturable hepatic first pass metabolism. Following oral administration, increasing doses result in a disproportionate increase in plasma levels. Steady-state C maxvalues following 20-, 30-, and 40-mg doses every 8 hours averaged 36, 88, and 133 ng/mL, respectively. Hence, increasing the dose from 20 to 30 mg every 8 hours more than doubled C maxand increasing the dose from 20 to 40 mg every 8 hours increased C maxmore than threefold. A similar disproportionate increase in AUC with dose was observed. Considerable inter-subject variability in plasma levels was also observed.

Post-absorption kinetics of nicardipine hydrochloride capsules are also non-linear, although there is a reproducible terminal plasma half-life that averaged 8.6 hours following 30- and 40-mg doses at steady-state (tid). The terminal half-life represents the elimination of less than 5% of the absorbed drug (measured by plasma concentrations). Elimination over the first 8 hours after dosing is much faster with a half-life of 2 to 4 hours. Steady-state plasma levels are achieved after 2 to 3 days of tid dosing (every 8 hours) and are twofold higher than after a single dose.

Nicardipine hydrochloride capsules are highly protein bound (>95%) in human plasma over a wide concentration range.

Nicardipine hydrochloride capsules are metabolized extensively by the hepatic cytochrome P450 enzymes, CYP2C8, 2D6, and 3A4; less than 1% of intact drug is detected in the urine. Following a radioactive oral dose in solution, 60% of the radioactivity was recovered in the urine and 35% in feces. Most of the dose (over 90%) was recovered within 48 hours of dosing. Nicardipine hydrochloride capsules do not induce its own metabolism, however, nicardipine causes inhibition of certain cytochrome P450 enzymes (including CYP3A4, CYP2D6, CYP2C8, and CYP2C19). Inhibition of these enzymes may result in increased plasma levels of certain drugs, including cyclosporine and tacrolimus (see Drug Interactions ). The altered pharmacokinetics may necessitate dosage adjustment of the affected drug or discontinuation of treatment.

Nicardipine hydrochloride plasma levels were higher in patients with mild renal impairment (baseline serum creatinine concentration ranged from 1.2 to 5.5 mg/dL) than in normal subjects. After 30-mg nicardipine hydrochloride tid at steady-state, C maxand AUC were approximately twofold higher in these patients.

Because nicardipine hydrochloride capsules are extensively metabolized by the liver, the plasma levels of the drug are influenced by changes in hepatic function. Nicardipine hydrochloride plasma levels were higher in patients with severe liver disease (hepatic cirrhosis confirmed by liver biopsy or presence of endoscopically-confirmed esophageal varices) than in normal subjects. After 20-mg nicardipine hydrochloride capsules bid at steady-state, C maxand AUC were 1.8 and fourfold higher, and the terminal half-life was prolonged to 19 hours in these patients.

Selected passages from the cited U.S. prescribing label. The studies concern the source product and populations named in each passage; they do not establish Walter-product bioequivalence, an approved indication, or the kinetics of another fixed combination. Tables and the full prescribing information remain available in the source.

Source: DailyMed: Nicardipine Hydrochloride — capsule

Reference accessed . Label revision: 2026-07-24.

Manufacturing & packaging brief

Plan the hard-capsule presentation.

Use this preparation guide for Nicardipine Hcl 40 mg Hard-gelatin capsules. These are the decisions to resolve with the technical team before a site, process and commercial scope are confirmed.

Presentation & formulation

Confirm the fill type, shell material, capsule size and printing requirements. Distinguish powder, granule and pellet fills where relevant to the proposed formulation.

Quality & technical transfer

Request review of the fill specification, shell compatibility, analytical methods and applicable release testing. Identify any established formula or transfer package.

Review the technical documents

Packaging configuration

Specify capsules per blister or bottle, the proposed barrier material and carton configuration. Include shell and print requirements in the quotation scope.

Explore packaging options

Details to confirm for this record

Salt and strength wording
Confirm whether the stated amount refers to the named salt, hydrate or equivalent active moiety. Use the agreed expression consistently in the specification, quotation and artwork.
Concentration and pack size
The record does not state a complete concentration basis. Confirm the amount per volume or weight before a specification, label or quotation is finalised; no denominator has been assumed here.

Quantities, MOQ & lead time

For Nicardipine Hcl 40 mg Hard-gelatin capsules, state the capsule count and finished-pack count, target market and reorder forecast. MOQ and lead time depend on the assessed formula, process, components, testing and project readiness; request those terms in writing.

Discuss this manufacturing brief

Explore the context

Build the right manufacturing brief.

Common questions

Before you request a quotation.

Nicardipine Hcl 40 mg Hard-gelatin capsules

What is listed in the catalogue?

The catalogue lists Nicardipine Hcl 40 mg as hard-gelatin capsules in its cardiovascular navigation area and non-beta-lactam manufacturing stream.

How do you confirm manufacturing availability?

Send Walter your requirement for Nicardipine Hcl 40 mg Hard-gelatin capsules. The team reviews the applicable product permission and unit, formulation and equipment fit, testing, packaging and production schedule before confirming the manufacturing scope in writing. Request the relevant product and facility documents with your enquiry.

What do I need for a quotation?

Share the exact composition and strength, hard-gelatin capsules presentation, target market, initial quantity, preferred pack and timing. Identify whether this is a new product, development brief or transfer.

The quotation must confirm MOQ, inclusions, prerequisites and lead time for the proposed product and site.

What is needed for Indian and export markets?

For India, share the intended brand or institutional supply requirement, pack sizes, initial order quantity and artwork needs for Nicardipine Hcl 40 mg Hard-gelatin capsules. Confirm the applicable product permission, manufacturing unit and labelling requirements with the team.

For export, identify each destination country, proposed pack, language and registration or dossier requirements. Ask which product-specific quality and stability documents are available. Container compatibility and destination-market requirements need review; a catalogue record does not establish export registration or a shelf-life commitment.

How do I submit my enquiry?

Use the product-specific enquiry button to carry this composition and dosage form into the form. After a successful submission, a receipt reference confirms that your brief has been saved for review. Use the RFQ checklist to prepare the remaining details.

Technical document review

Which documents can I ask Walter to review?

Ask about manufacturing and packing records, specifications, analytical methods, Certificates of Analysis (COA), stability evidence, the Process Validation Protocol (PVP) and Process Validation Report (PVR). The wider checklist below covers supplier qualification, technical transfer and ongoing supply.

View the full document checklist 14 review areas
Site, licence and audit scope
Manufacturing licence, applicable product permissions, GMP certificates, Site Master File, supplier-qualification questionnaire and relevant audit responses.
Manufacturing, packing and batch release
Master Formula Record (MFR), master packing instructions, Batch Manufacturing Record (BMR), Batch Packing Record (BPR), reconciliation and authorised release records.
Process validation and continued verification
Process Validation Protocol (PVP), Process Validation Report (PVR), process performance qualification documents and continued process verification trends.
Equipment, facilities and utilities
Validation Master Plan (VMP), user requirements, DQ/IQ/OQ/PQ records, calibration and maintenance evidence for relevant equipment and utilities.
Cleaning, carryover and hold times
Cleaning Validation Protocol (CVP), Cleaning Validation Report (CVR), residue limits, recovery studies and applicable clean, dirty and process hold-time studies.
Specifications and analytical evidence
Specifications, Method of Analysis (MOA), Standard Testing Procedure (STP), Certificates of Analysis (COA), analytical validation, verification and method-transfer records.
Stability, packaging and transport
Stability protocols/reports, ongoing stability commitments, pack specifications, approved artwork, compatibility and applicable packaging or transport studies.
Development and technology transfer
Development report, technology-transfer protocol/report, gap assessment, control strategy, critical quality attributes and critical process parameters.
Quality reviews, investigations and changes
Product Quality Review (PQR) / Annual Product Review (APR), deviations, CAPA, change control, OOS/OOT trends, complaints, recalls and relevant SOP/training records.
Material suppliers and impurity risks
API/excipient supplier qualification, traceability, material COAs, relevant origin declarations and impurity risk assessments with supporting tests.
Sterile-product evidence, where applicable
Contamination Control Strategy (CCS), media-fill/aseptic simulation reports, sterilisation and filtration validation, environmental monitoring, sterility/endotoxin and container-closure integrity evidence.
Computerised systems and data integrity
Computerised-system validation, access controls, audit-trail review, backup/restore checks and relevant data-integrity procedures.
Market-specific regulatory support
Applicable dossier sections, API master-file/CEP support, bioequivalence or biowaiver evidence and Certificate of a Pharmaceutical Product (CPP/CoPP), where required and available.
Quality agreement and access arrangements
Quality/technical agreement covering responsibilities, release, changes, subcontracting, investigations, complaints, recalls, audits and document access.

Agree the list for the exact product, site, process, pack, market and project stage. QA confirms what exists, applies and may be shared; some records may require an NDA, redaction or controlled review. See document definitions and review guidance.

Important qualification

This B2B catalogue record is not proof of current approval or confirmation that Nicardipine Hcl 40 mg Hard-gelatin capsules is available for sale. It is not prescribing information or patient advice. Any Drugs Rules status, current approval, exemption, applicable unit, licence scope, formulation, claims, brand use, destination-market registration and commercial feasibility require documentary verification and Walter's written confirmation. Read the full regulatory disclaimer.

Composition and classification are taken from Walter's product catalogue. The manufacturing guide helps buyers prepare a technical brief. Clinical references, where shown, describe the cited product and study. Manufacturing guide updated .