Oral solids · Contract manufacturing enquiry

Fluvoxamine Maleate 100 mg (ER) · Tablets

Request manufacturing feasibility

Discuss third-party manufacturing with Walter Healthcare, India. Confirm the formulation, tablet presentation, packaging and project requirements for a product-specific quotation.

Catalogue reference
WH-0782
Composition and strength
Fluvoxamine Maleate 100 mg (ER)
Dosage form
Tablets
Indicative administration route
Oral
Therapeutic navigation area
Neurology & psychiatry
Pharmacological class
CNS agent
Manufacturing stream
Non-beta-lactam
BCS class
Class II

Catalogue details support an initial B2B discussion. Walter confirms the applicable unit, current licence scope, formula, target market and commercial feasibility before making a commitment.

Clinical reference

Mechanism and pharmacokinetics.

Explore the published evidence for the ingredients in Fluvoxamine Maleate 100 mg (ER) Tablets. Each reference identifies its source formulation and study context. Ingredient studies describe the named reference product; they do not establish the pharmacokinetics, clinical suitability or bioequivalence of this finished formulation.

How to read our product information and sources ↗

Prescribing-label excerpts

Fluvoxamine Maleate

Reference for: Fluvoxamine Maleate. Source presentation: capsule, extended release. Source route: oral.

Mechanism of action

The mechanism of action of fluvoxamine maleate in obsessive compulsive disorder is presumed to be linked to its specific serotonin reuptake inhibition in brain neurons. Fluvoxamine has been shown to be a potent inhibitor of the serotonin reuptake transporter in preclinical studies, both in vitro and in vivo.

Pharmacokinetics

Bioavailability: A single-dose crossover study in 28 healthy subjects was conducted to compare the pharmacokinetics of fluvoxamine after administration of fluvoxamine maleate extended-release capsules and immediate-release fluvoxamine maleate tablets.

In the single-dose crossover study, mean Cmax was 38% lower and relative bioavailability was 84% for fluvoxamine maleate extended-release capsules versus immediate-release fluvoxamine maleate tablets.

In a multiple-dose proportionality study, fluvoxamine maleate extended-release capsules were administered over a dose range of 100 mg/day to 300 mg/day to 20 healthy volunteers. Steady-state plasma concentrations were achieved within a week of dosing. Mean maximum plasma concentrations were 47 ng/mL, 161 ng/mL, and 319 ng/mL, respectively, at the 100 mg, 200 mg, and 300 mg administered dose levels. Fluvoxamine exhibited nonlinear pharmacokinetics producing disproportionately higher concentrations over the dose range. The AUC and Cmax values increased 5.7-fold following the 3-fold increase in dose from 100 mg to 300 mg.

Food caused the mean AUC and Cmax of fluvoxamine to increase only slightly; therefore, administration of fluvoxamine maleate extended-release capsules with food does not significantly affect the absorption of fluvoxamine.

Distribution/Protein Binding: The mean apparent volume of distribution for fluvoxamine is approximately 25 L/kg, suggesting extensive tissue distribution.

Approximately 80% of fluvoxamine is bound to plasma protein, mostly albumin, over a concentration range of 20 to 2000 ng/mL.

Metabolism: Fluvoxamine maleate is extensively metabolized by the liver; the main metabolic routes are oxidative demethylation and deamination. Nine metabolites were identified following a 5 mg radiolabelled dose of fluvoxamine maleate, constituting approximately 85% of the urinary excretion products of fluvoxamine. The main human metabolite was fluvoxamine acid which, together with its N-acetylated analog, accounted for about 60% of the urinary excretion products. A third metabolite, fluvoxethanol, formed by oxidative deamination, accounted for about 10%. Fluvoxamine acid and fluvoxethanol were tested in an in vitro assay of serotonin and norepinephrine reuptake inhibition in rats; they were inactive except for a weak effect of the former metabolite on inhibition of serotonin uptake (1 to 2 orders of magnitude less potent than the parent compound). Approximately 2% of fluvoxamine was excreted in urine unchanged (see DRUG INTERACTIONS [7]).

Elimination: Following a 14C-labelled oral dose of fluvoxamine maleate (5 mg), an average of 94% of drug-related products was recovered in the urine within 71 hours.

After administration of a 100 mg, single oral dose of fluvoxamine maleate extended-release capsules, the mean plasma half-life of fluvoxamine in healthy male and female volunteers was 16.3 hours.

Gender: In a study with 15 male and 13 female healthy volunteers who were administered fluvoxamine maleate extended-release capsules 100 mg, AUC and Cmax of fluvoxamine were increased by approximately 60% in females compared to males. There were no differences in the elimination half-life between males and females.

Elderly Subjects: In a study using immediate-release fluvoxamine maleate tablets at 50 mg and 100 mg and comparing elderly (ages 66 to 73 years) and young subjects (ages 19 to 35 years), mean maximum plasma concentrations in the elderly were 40% higher. The multiple-dose elimination half-life of fluvoxamine was 17.4 hours and 25.9 hours in the elderly compared to 13.6 hours and 15.6 hours in the young subjects at steady state for 50 mg and 100 mg doses, respectively.

In elderly patients administered immediate-release fluvoxamine maleate tablets, the clearance of fluvoxamine was reduced by about 50%; therefore, fluvoxamine maleate extended-release capsules should be slowly titrated during initiation of therapy (see DOSAGE AND ADMINISTRATION [2.3] ).

Selected passages from the cited U.S. prescribing label. The studies concern the source product and populations named in each passage; they do not establish Walter-product bioequivalence, an approved indication, or the kinetics of another fixed combination. Tables and the full prescribing information remain available in the source.

Source: DailyMed: Fluvoxamine Maleate — capsule, extended release

Reference accessed . Label revision: 2026-06-24.

Manufacturing & packaging brief

Plan the tablet presentation.

Use this preparation guide for Fluvoxamine Maleate 100 mg (ER) Tablets. These are the decisions to resolve with the technical team before a site, process and commercial scope are confirmed.

Presentation & formulation

Define release type, coating, scoring and any reference-product requirements. Keep each strength and presentation as a separate item in the brief.

Quality & technical transfer

Agree the product specification, analytical methods and applicable dissolution or disintegration requirements. Identify the formula and process information available for transfer.

Review the technical documents

Packaging configuration

Compare the proposed blister, strip or bottle with the formulation and its protection requirements. Specify tablets per primary pack and primary packs per carton.

Explore packaging options

Details to confirm for this record

Release presentation
The catalogue includes “ER”. Carry that designation into the RFQ and confirm the intended release specification and supporting evidence; a different release type needs its own assessment.

Quantities, MOQ & lead time

For Fluvoxamine Maleate 100 mg (ER) Tablets, state the tablet count and finished-pack count, target market and reorder forecast. MOQ and lead time depend on the assessed formula, process, components, testing and project readiness; request those terms in writing.

Discuss this manufacturing brief

Explore the context

Build the right manufacturing brief.

Common questions

Before you request a quotation.

Fluvoxamine Maleate 100 mg (ER) Tablets

What is listed in the catalogue?

The catalogue lists Fluvoxamine Maleate 100 mg (ER) as tablets in its neurology & psychiatry navigation area and non-beta-lactam manufacturing stream.

Is manufacturing availability confirmed?

No. Walter checks current facility permissions, formulation and equipment fit, testing, packaging and target-market requirements before written confirmation.

What do I need for a quotation?

Share the exact composition and strength, tablets presentation, target market, initial quantity, preferred pack and timing. Identify whether this is a new product, development brief or transfer.

The quotation must confirm MOQ, inclusions, prerequisites and lead time for the proposed product and site.

Can I change the pack or target market?

Include each proposed pack and country in the enquiry. Container compatibility, artwork, supporting stability evidence, permission scope and destination requirements need review for the requested configuration.

A catalogue record does not establish export registration or a shelf-life commitment.

How do I submit my enquiry?

Use the product-specific enquiry button to carry this composition and dosage form into the form. After a successful submission, a receipt reference confirms that your brief has been saved for review. Use the RFQ checklist to prepare the remaining details.

Technical document review

Which documents can I ask Walter to review?

Ask about manufacturing and packing records, specifications, analytical methods, Certificates of Analysis (COA), stability evidence, the Process Validation Protocol (PVP) and Process Validation Report (PVR). The wider checklist below covers supplier qualification, technical transfer and ongoing supply.

View the full document checklist 14 review areas
Site, licence and audit scope
Manufacturing licence, applicable product permissions, GMP certificates, Site Master File, supplier-qualification questionnaire and relevant audit responses.
Manufacturing, packing and batch release
Master Formula Record (MFR), master packing instructions, Batch Manufacturing Record (BMR), Batch Packing Record (BPR), reconciliation and authorised release records.
Process validation and continued verification
Process Validation Protocol (PVP), Process Validation Report (PVR), process performance qualification documents and continued process verification trends.
Equipment, facilities and utilities
Validation Master Plan (VMP), user requirements, DQ/IQ/OQ/PQ records, calibration and maintenance evidence for relevant equipment and utilities.
Cleaning, carryover and hold times
Cleaning Validation Protocol (CVP), Cleaning Validation Report (CVR), residue limits, recovery studies and applicable clean, dirty and process hold-time studies.
Specifications and analytical evidence
Specifications, Method of Analysis (MOA), Standard Testing Procedure (STP), Certificates of Analysis (COA), analytical validation, verification and method-transfer records.
Stability, packaging and transport
Stability protocols/reports, ongoing stability commitments, pack specifications, approved artwork, compatibility and applicable packaging or transport studies.
Development and technology transfer
Development report, technology-transfer protocol/report, gap assessment, control strategy, critical quality attributes and critical process parameters.
Quality reviews, investigations and changes
Product Quality Review (PQR) / Annual Product Review (APR), deviations, CAPA, change control, OOS/OOT trends, complaints, recalls and relevant SOP/training records.
Material suppliers and impurity risks
API/excipient supplier qualification, traceability, material COAs, relevant origin declarations and impurity risk assessments with supporting tests.
Sterile-product evidence, where applicable
Contamination Control Strategy (CCS), media-fill/aseptic simulation reports, sterilisation and filtration validation, environmental monitoring, sterility/endotoxin and container-closure integrity evidence.
Computerised systems and data integrity
Computerised-system validation, access controls, audit-trail review, backup/restore checks and relevant data-integrity procedures.
Market-specific regulatory support
Applicable dossier sections, API master-file/CEP support, bioequivalence or biowaiver evidence and Certificate of a Pharmaceutical Product (CPP/CoPP), where required and available.
Quality agreement and access arrangements
Quality/technical agreement covering responsibilities, release, changes, subcontracting, investigations, complaints, recalls, audits and document access.

Agree the list for the exact product, site, process, pack, market and project stage. QA confirms what exists, applies and may be shared; some records may require an NDA, redaction or controlled review. See document definitions and review guidance.

Important qualification

This B2B catalogue record is not proof of current approval or confirmation that Fluvoxamine Maleate 100 mg (ER) Tablets is available for sale. It is not prescribing information or patient advice. Any Drugs Rules status, current approval, exemption, applicable unit, licence scope, formulation, claims, brand use, destination-market registration and commercial feasibility require documentary verification and Walter's written confirmation. Read the full regulatory disclaimer.

Composition and classification are taken from Walter's product catalogue. The manufacturing guide helps buyers prepare a technical brief. Clinical references, where shown, describe the cited product and study. Manufacturing guide updated .