Sterile injectables · Contract manufacturing enquiry

Tranexamic Acid 100 mg · Liquid injectables

Request manufacturing feasibility

Discuss third-party manufacturing with Walter Healthcare, India. Confirm the formulation, liquid-injectable presentation, packaging and project requirements for a product-specific quotation.

Catalogue reference
WH-1966
Composition and strength
Tranexamic Acid 100 mg
Dosage form
Liquid injectables
Indicative administration route
Parenteral
Therapeutic navigation area
Haematology & thrombosis
Pharmacological class
Haemostatic
Manufacturing stream
Non-beta-lactam

Catalogue details support an initial B2B discussion. Walter confirms the applicable unit, current licence scope, formula, target market and commercial feasibility before making a commitment.

Clinical reference

Mechanism and pharmacokinetics.

Explore the published evidence for the ingredients in Tranexamic Acid 100 mg Liquid injectables. Each reference identifies its source formulation and study context. Ingredient studies describe the named reference product; they do not establish the pharmacokinetics, clinical suitability or bioequivalence of this finished formulation.

How to read our product information and sources ↗

Prescribing-label excerpts

Tranexamic Acid

Reference for: Tranexamic Acid. Source presentation: injection, solution. Source route: intravenous.

Mechanism of action

Tranexamic acid is a synthetic lysine amino acid derivative, which diminishes the dissolution of hemostatic fibrin by plasmin. In the presence of tranexamic acid, the lysine receptor binding sites of plasmin for fibrin are occupied, preventing binding to fibrin monomers, thus preserving and stabilizing fibrin’s matrix structure.

The antifibrinolytic effects of tranexamic acid are mediated by reversible interactions at multiple binding sites within plasminogen. Native human plasminogen contains 4 to 5 lysine binding sites with low affinity for tranexamic acid (Kd = 750 micromol/L) and 1 with high affinity (Kd = 1.1 micromol/L). The high affinity lysine site of plasminogen is involved in its binding to fibrin. Saturation of the high affinity binding site with tranexamic acid displaces plasminogen from the surface of fibrin. Although plasmin may be formed by conformational changes in plasminogen, binding to and dissolution of the fibrin matrix is inhibited.

Pharmacokinetics

Distribution — The initial volume of distribution is about 9 to 12 liters. The plasma protein binding of tranexamic acid is about 3% at therapeutic plasma levels and seems to be fully accounted for by its binding to plasminogen. Tranexamic acid does not bind to serum albumin.

Elimination — After an intravenous dose of 1 g, the plasma concentration time curve shows a triexponential decay with a half-life of about 2 hours for the terminal elimination phase.

Excretion — Urinary excretion is the main route of elimination via glomerular filtration. Overall renal clearance is equal to overall plasma clearance (110 to 116 mL/min), and more than 95% of the dose is excreted in the urine as unchanged drug. Excretion of tranexamic acid is about 90% at 24 hours after intravenous administration of 10 mg/kg body weight.

Patients with Renal Impairment — The blood levels of tranexamic acid are increased in patients with renal insufficiency. Urinary excretion following a single intravenous injection of tranexamic acid declines as renal function decreases. Following a single 10 mg/kg intravenous injection of tranexamic acid, the 24-hour urinary fractions of tranexamic acid with serum creatinine concentrations 1.4 – 2.8, 2.8 – 5.7, and greater than 5.7 mg/dL were 51, 39, and 19%, respectively. The 24-hour tranexamic acid plasma concentrations for these patients demonstrated a direct relationship to the degree of renal impairment. Therefore, dose adjustment is needed in patients with renal impairment [see Dosage and Administration (2.2), Use in Specific Populations (8.6)].

Drug Interaction Studies — No studies of interactions between tranexamic acid and other drugs have been conducted.

Selected passages from the cited U.S. prescribing label. The studies concern the source product and populations named in each passage; they do not establish Walter-product bioequivalence, an approved indication, or the kinetics of another fixed combination. Tables and the full prescribing information remain available in the source.

Source: DailyMed: Tranexamic Acid — injection, solution

Reference accessed . Label revision: 2026-08-14.

Manufacturing & packaging brief

Plan the liquid-injectable presentation.

Use this preparation guide for Tranexamic Acid 100 mg Liquid injectables. These are the decisions to resolve with the technical team before a site, process and commercial scope are confirmed.

Presentation & formulation

Confirm concentration, fill volume, route and whether the proposed container is single-dose or multidose. Identify the formulation and transfer information available.

Quality & technical transfer

Ask for review of the sterile-process strategy, applicable sterility, endotoxin and particulate controls, analytical methods and container-closure integrity requirements.

Review the technical documents

Packaging configuration

Specify ampoule, vial or other proposed container, contact materials, closure and secondary pack. Confirm equipment and facility fit for that configuration.

Explore packaging options

Details to confirm for this record

Concentration and pack size
The record does not state a complete concentration basis. Confirm the amount per volume or weight before a specification, label or quotation is finalised; no denominator has been assumed here.

Quantities, MOQ & lead time

For Tranexamic Acid 100 mg Liquid injectables, state the container count and fill volume, target market and reorder forecast. MOQ and lead time depend on the assessed formula, process, components, testing and project readiness; request those terms in writing.

Discuss this manufacturing brief

Explore the context

Build the right manufacturing brief.

Common questions

Before you request a quotation.

Tranexamic Acid 100 mg Liquid injectables

What is listed in the catalogue?

The catalogue lists Tranexamic Acid 100 mg as liquid injectables in its haematology & thrombosis navigation area and non-beta-lactam manufacturing stream.

Is manufacturing availability confirmed?

No. Walter checks current facility permissions, formulation and equipment fit, testing, packaging and target-market requirements before written confirmation.

What do I need for a quotation?

Share the exact composition and strength, liquid injectables presentation, target market, initial quantity, preferred pack and timing. Identify whether this is a new product, development brief or transfer.

The quotation must confirm MOQ, inclusions, prerequisites and lead time for the proposed product and site.

Can I change the pack or target market?

Include each proposed pack and country in the enquiry. Container compatibility, artwork, supporting stability evidence, permission scope and destination requirements need review for the requested configuration.

A catalogue record does not establish export registration or a shelf-life commitment.

How do I submit my enquiry?

Use the product-specific enquiry button to carry this composition and dosage form into the form. After a successful submission, a receipt reference confirms that your brief has been saved for review. Use the RFQ checklist to prepare the remaining details.

Technical document review

Which documents can I ask Walter to review?

Ask about manufacturing and packing records, specifications, analytical methods, Certificates of Analysis (COA), stability evidence, the Process Validation Protocol (PVP) and Process Validation Report (PVR). The wider checklist below covers supplier qualification, technical transfer and ongoing supply.

View the full document checklist 14 review areas
Site, licence and audit scope
Manufacturing licence, applicable product permissions, GMP certificates, Site Master File, supplier-qualification questionnaire and relevant audit responses.
Manufacturing, packing and batch release
Master Formula Record (MFR), master packing instructions, Batch Manufacturing Record (BMR), Batch Packing Record (BPR), reconciliation and authorised release records.
Process validation and continued verification
Process Validation Protocol (PVP), Process Validation Report (PVR), process performance qualification documents and continued process verification trends.
Equipment, facilities and utilities
Validation Master Plan (VMP), user requirements, DQ/IQ/OQ/PQ records, calibration and maintenance evidence for relevant equipment and utilities.
Cleaning, carryover and hold times
Cleaning Validation Protocol (CVP), Cleaning Validation Report (CVR), residue limits, recovery studies and applicable clean, dirty and process hold-time studies.
Specifications and analytical evidence
Specifications, Method of Analysis (MOA), Standard Testing Procedure (STP), Certificates of Analysis (COA), analytical validation, verification and method-transfer records.
Stability, packaging and transport
Stability protocols/reports, ongoing stability commitments, pack specifications, approved artwork, compatibility and applicable packaging or transport studies.
Development and technology transfer
Development report, technology-transfer protocol/report, gap assessment, control strategy, critical quality attributes and critical process parameters.
Quality reviews, investigations and changes
Product Quality Review (PQR) / Annual Product Review (APR), deviations, CAPA, change control, OOS/OOT trends, complaints, recalls and relevant SOP/training records.
Material suppliers and impurity risks
API/excipient supplier qualification, traceability, material COAs, relevant origin declarations and impurity risk assessments with supporting tests.
Sterile-product evidence, where applicable
Contamination Control Strategy (CCS), media-fill/aseptic simulation reports, sterilisation and filtration validation, environmental monitoring, sterility/endotoxin and container-closure integrity evidence.
Computerised systems and data integrity
Computerised-system validation, access controls, audit-trail review, backup/restore checks and relevant data-integrity procedures.
Market-specific regulatory support
Applicable dossier sections, API master-file/CEP support, bioequivalence or biowaiver evidence and Certificate of a Pharmaceutical Product (CPP/CoPP), where required and available.
Quality agreement and access arrangements
Quality/technical agreement covering responsibilities, release, changes, subcontracting, investigations, complaints, recalls, audits and document access.

Agree the list for the exact product, site, process, pack, market and project stage. QA confirms what exists, applies and may be shared; some records may require an NDA, redaction or controlled review. See document definitions and review guidance.

Important qualification

This B2B catalogue record is not proof of current approval or confirmation that Tranexamic Acid 100 mg Liquid injectables is available for sale. It is not prescribing information or patient advice. Any Drugs Rules status, current approval, exemption, applicable unit, licence scope, formulation, claims, brand use, destination-market registration and commercial feasibility require documentary verification and Walter's written confirmation. Read the full regulatory disclaimer.

Composition and classification are taken from Walter's product catalogue. The manufacturing guide helps buyers prepare a technical brief. Clinical references, where shown, describe the cited product and study. Manufacturing guide updated .