Sterile injectables · Contract manufacturing in India

Paracetamol 300 mg / 2 ml · Liquid injectables

Request manufacturing feasibility

Discuss third-party manufacturing of Paracetamol 300 mg / 2 ml Liquid injectables with Walter Healthcare, India. Share your target market, required container count and fill volume, packaging and launch timeline for a product-specific quotation.

Catalogue reference
WH-1949
Composition and strength
Paracetamol 300 mg / 2 ml
Dosage form
Liquid injectables
Indicative administration route
Parenteral
Therapeutic navigation area
Pain & musculoskeletal care
Pharmacological class
Analgesic & antipyretic
Manufacturing stream
Non-beta-lactam

Catalogue details support an initial B2B discussion. Walter confirms the applicable unit, current licence scope, formula, target market and commercial feasibility before making a commitment.

Clinical reference

Mechanism and pharmacokinetics.

Explore the published evidence for the ingredients in Paracetamol 300 mg / 2 ml Liquid injectables. Each reference identifies its source formulation and study context. Ingredient studies describe the named reference product; they do not establish the pharmacokinetics, clinical suitability or bioequivalence of this finished formulation.

How to read our product information and sources ↗

Prescribing-label excerpts

Acetaminophen

Reference for: Paracetamol. Source presentation: injection, solution. Source route: intravenous.

Mechanism of action

The precise mechanism of the analgesic and antipyretic properties of acetaminophen is not established but is thought to primarily involve central actions.

Pharmacokinetics

Distribution — The pharmacokinetics of acetaminophen have been studied in patients and healthy subjects up to 60 years old. The pharmacokinetic profile of acetaminophen has been demonstrated to be dose proportional in adults following administration of single-doses of 500, 650, and 1,000 mg.

The maximum concentration (C max) occurs at the end of the 15 minute intravenous infusion of acetaminophen. Compared to the same dose of oral acetaminophen, the C maxfollowing administration of acetaminophen is up to 70% higher, while overall exposure (area under the concentration time curve [AUC]) is very similar.

Pharmacokinetic parameters of acetaminophen (AUC, C max, terminal elimination half-life [T½], systemic clearance [CL], and volume of distribution at steady state [V ss]) following administration of a single intravenous dose of 15 mg/kg in children and adolescents and 1,000 mg in adults are summarized in Table 5.

The concentrations of acetaminophen observed in neonates greater than 32 weeks gestational age at birth treated with 12.5 mg/kg dose are similar to infants, children and adolescents treated with a 15 mg/kg dose, and similar to adults treated with a 1,000 mg dose.

At therapeutic levels, binding of acetaminophen to plasma proteins is low (ranging from 10% to 25%). Acetaminophen appears to be widely distributed throughout most body tissues except fat.

Metabolism and Excretion — Acetaminophen is primarily metabolized in the liver by first-order kinetics and involves three principal separate pathways: Conjugation with glucuronide, conjugation with sulfate, and oxidation via the cytochrome P450 enzyme pathway, primarily CYP2E1, to form a reactive intermediate metabolite (N-acetyl-p-benzoquinone imine or NAPQI). With therapeutic doses, NAPQI undergoes rapid conjugation with glutathione and is then further metabolized to form cysteine and mercapturic acid conjugates.

Acetaminophen metabolites are mainly excreted in the urine. Less than 5% is excreted in the urine as unconjugated (free) acetaminophen and more than 90% of the administered dose is excreted within 24 hours.

Selected passages from the cited U.S. prescribing label. The studies concern the source product and populations named in each passage; they do not establish Walter-product bioequivalence, an approved indication, or the kinetics of another fixed combination. Tables and the full prescribing information remain available in the source.

Source: DailyMed: Acetaminophen — injection, solution

Reference accessed . Label revision: 2026-08-28.

Manufacturing & packaging brief

Plan the liquid-injectable presentation.

Use this preparation guide for Paracetamol 300 mg / 2 ml Liquid injectables. These are the decisions to resolve with the technical team before a site, process and commercial scope are confirmed.

Presentation & formulation

Confirm concentration, fill volume, route and whether the proposed container is single-dose or multidose. Identify the formulation and transfer information available.

Quality & technical transfer

Ask for review of the sterile-process strategy, applicable sterility, endotoxin and particulate controls, analytical methods and container-closure integrity requirements.

Review the technical documents

Packaging configuration

Specify ampoule, vial or other proposed container, contact materials, closure and secondary pack. Confirm equipment and facility fit for that configuration.

Explore packaging options

Details to confirm for this record

Concentration and pack size
The record includes a concentration or percentage expression. Confirm its complete basis, then specify the finished fill volume or weight separately. Do not treat pack size as the strength.

Quantities, MOQ & lead time

For Paracetamol 300 mg / 2 ml Liquid injectables, state the container count and fill volume, target market and reorder forecast. MOQ and lead time depend on the assessed formula, process, components, testing and project readiness; request those terms in writing.

Discuss this manufacturing brief

Explore the context

Build the right manufacturing brief.

Common questions

Before you request a quotation.

Paracetamol 300 mg / 2 ml Liquid injectables

What is listed in the catalogue?

The catalogue lists Paracetamol 300 mg / 2 ml as liquid injectables in its pain & musculoskeletal care navigation area and non-beta-lactam manufacturing stream.

How do you confirm manufacturing availability?

Send Walter your requirement for Paracetamol 300 mg / 2 ml Liquid injectables. The team reviews the applicable product permission and unit, formulation and equipment fit, testing, packaging and production schedule before confirming the manufacturing scope in writing. Request the relevant product and facility documents with your enquiry.

What do I need for a quotation?

Share the exact composition and strength, liquid injectables presentation, target market, initial quantity, preferred pack and timing. Identify whether this is a new product, development brief or transfer.

The quotation must confirm MOQ, inclusions, prerequisites and lead time for the proposed product and site.

What is needed for Indian and export markets?

For India, share the intended brand or institutional supply requirement, pack sizes, initial order quantity and artwork needs for Paracetamol 300 mg / 2 ml Liquid injectables. Confirm the applicable product permission, manufacturing unit and labelling requirements with the team.

For export, identify each destination country, proposed pack, language and registration or dossier requirements. Ask which product-specific quality and stability documents are available. Container compatibility and destination-market requirements need review; a catalogue record does not establish export registration or a shelf-life commitment.

How do I submit my enquiry?

Use the product-specific enquiry button to carry this composition and dosage form into the form. After a successful submission, a receipt reference confirms that your brief has been saved for review. Use the RFQ checklist to prepare the remaining details.

Technical document review

Which documents can I ask Walter to review?

Ask about manufacturing and packing records, specifications, analytical methods, Certificates of Analysis (COA), stability evidence, the Process Validation Protocol (PVP) and Process Validation Report (PVR). The wider checklist below covers supplier qualification, technical transfer and ongoing supply.

View the full document checklist 14 review areas
Site, licence and audit scope
Manufacturing licence, applicable product permissions, GMP certificates, Site Master File, supplier-qualification questionnaire and relevant audit responses.
Manufacturing, packing and batch release
Master Formula Record (MFR), master packing instructions, Batch Manufacturing Record (BMR), Batch Packing Record (BPR), reconciliation and authorised release records.
Process validation and continued verification
Process Validation Protocol (PVP), Process Validation Report (PVR), process performance qualification documents and continued process verification trends.
Equipment, facilities and utilities
Validation Master Plan (VMP), user requirements, DQ/IQ/OQ/PQ records, calibration and maintenance evidence for relevant equipment and utilities.
Cleaning, carryover and hold times
Cleaning Validation Protocol (CVP), Cleaning Validation Report (CVR), residue limits, recovery studies and applicable clean, dirty and process hold-time studies.
Specifications and analytical evidence
Specifications, Method of Analysis (MOA), Standard Testing Procedure (STP), Certificates of Analysis (COA), analytical validation, verification and method-transfer records.
Stability, packaging and transport
Stability protocols/reports, ongoing stability commitments, pack specifications, approved artwork, compatibility and applicable packaging or transport studies.
Development and technology transfer
Development report, technology-transfer protocol/report, gap assessment, control strategy, critical quality attributes and critical process parameters.
Quality reviews, investigations and changes
Product Quality Review (PQR) / Annual Product Review (APR), deviations, CAPA, change control, OOS/OOT trends, complaints, recalls and relevant SOP/training records.
Material suppliers and impurity risks
API/excipient supplier qualification, traceability, material COAs, relevant origin declarations and impurity risk assessments with supporting tests.
Sterile-product evidence, where applicable
Contamination Control Strategy (CCS), media-fill/aseptic simulation reports, sterilisation and filtration validation, environmental monitoring, sterility/endotoxin and container-closure integrity evidence.
Computerised systems and data integrity
Computerised-system validation, access controls, audit-trail review, backup/restore checks and relevant data-integrity procedures.
Market-specific regulatory support
Applicable dossier sections, API master-file/CEP support, bioequivalence or biowaiver evidence and Certificate of a Pharmaceutical Product (CPP/CoPP), where required and available.
Quality agreement and access arrangements
Quality/technical agreement covering responsibilities, release, changes, subcontracting, investigations, complaints, recalls, audits and document access.

Agree the list for the exact product, site, process, pack, market and project stage. QA confirms what exists, applies and may be shared; some records may require an NDA, redaction or controlled review. See document definitions and review guidance.

Important qualification

This B2B catalogue record is not proof of current approval or confirmation that Paracetamol 300 mg / 2 ml Liquid injectables is available for sale. It is not prescribing information or patient advice. Any Drugs Rules status, current approval, exemption, applicable unit, licence scope, formulation, claims, brand use, destination-market registration and commercial feasibility require documentary verification and Walter's written confirmation. Read the full regulatory disclaimer.

Composition and classification are taken from Walter's product catalogue. The manufacturing guide helps buyers prepare a technical brief. Clinical references, where shown, describe the cited product and study. Manufacturing guide updated .