Sterile injectables · Contract manufacturing in India

Levetiracetam 100 mg · Liquid injectables

Request manufacturing feasibility

Discuss third-party manufacturing of Levetiracetam 100 mg Liquid injectables with Walter Healthcare, India. Share your target market, required container count and fill volume, packaging and launch timeline for a product-specific quotation.

Catalogue reference
WH-1900
Composition and strength
Levetiracetam 100 mg
Dosage form
Liquid injectables
Indicative administration route
Parenteral
Therapeutic navigation area
Neurology & psychiatry
Pharmacological class
Anticonvulsant
Manufacturing stream
Non-beta-lactam

Catalogue details support an initial B2B discussion. Walter confirms the applicable unit, current licence scope, formula, target market and commercial feasibility before making a commitment.

Clinical reference

Mechanism and pharmacokinetics.

Explore the published evidence for the ingredients in Levetiracetam 100 mg Liquid injectables. Each reference identifies its source formulation and study context. Ingredient studies describe the named reference product; they do not establish the pharmacokinetics, clinical suitability or bioequivalence of this finished formulation.

How to read our product information and sources ↗

Prescribing-label excerpts

Levetiracetam

Reference for: Levetiracetam. Source presentation: injection. Source route: intravenous.

Mechanism of action

The precise mechanism(s) by which levetiracetam exerts its antiepileptic effect is unknown.

A saturable and stereoselective neuronal binding site in rat brain tissue has been described for levetiracetam. Experimental data indicate that this binding site is the synaptic vesicle protein SV2A, thought to be involved in the regulation of vesicle exocytosis. Although the molecular significance of levetiracetam binding to synaptic vesicle protein SV2A is not understood, levetiracetam and related analogs showed a rank order of affinity for SV2A which correlated with the potency of their antiseizure activity in audiogenic seizure-prone mice. These findings suggest that the interaction of levetiracetam with the SV2A protein may contribute to the antiepileptic mechanism of action of the drug.

Pharmacokinetics

Equivalent doses of intravenous (IV) levetiracetam and oral levetiracetam result in equivalent C max, C min, and total systemic exposure to levetiracetam when the IV levetiracetam is administered as a 15-minute infusion.

Overview — Levetiracetam is rapidly and almost completely absorbed after oral administration. Levetiracetam injection and tablets are bioequivalent. The pharmacokinetics of levetiracetam are linear and time-invariant, with low intra- and inter-subject variability. Levetiracetam is not significantly protein-bound (<10% bound) and its volume of distribution is close to the volume of intracellular and extracellular water. Sixty-six percent (66%) of the dose is renally excreted unchanged. The major metabolic pathway of levetiracetam (24% of dose) is an enzymatic hydrolysis of the acetamide group. It is not liver cytochrome P450 dependent. The metabolites have no known pharmacological activity and are renally excreted. Plasma half-life of levetiracetam across studies is approximately 6 to 8 hours. It is increased in the elderly (primarily due to impaired renal clearance) and in subjects with renal impairment.

The pharmacokinetics of levetiracetam are similar when used as monotherapy or as adjunctive therapy for the treatment of partial-onset seizures.

Distribution — The equivalence of levetiracetam injection and the oral formulation was demonstrated in a bioavailability study of 17 healthy volunteers. In this study, levetiracetam 1500 mg was diluted in 100 mL 0.9% sterile saline solution and was infused over 15 minutes. The selected infusion rate provided plasma concentrations of levetiracetam at the end of the infusion period similar to those achieved at T maxafter an equivalent oral dose. It is demonstrated that levetiracetam 1500 mg intravenous infusion is equivalent to levetiracetam 3 x 500 mg oral tablets. The time independent pharmacokinetic profile of levetiracetam was demonstrated following 1500 mg intravenous infusion for 4 days with BID dosing. The AUC (0 to 12)at steady-state was equivalent to AUC inffollowing an equivalent single dose.

Levetiracetam and its major metabolite are less than 10% bound to plasma proteins; clinically significant interactions with other drugs through competition for protein binding sites are therefore unlikely.

Metabolism — Levetiracetam is not extensively metabolized in humans. The major metabolic pathway is the enzymatic hydrolysis of the acetamide group, which produces the carboxylic acid metabolite, ucb L057 (24% of dose) and is not dependent on any liver cytochrome P450 isoenzymes. The major metabolite is inactive in animal seizure models. Two minor metabolites were identified as the product of hydroxylation of the 2-oxo-pyrrolidine ring (2% of dose) and opening of the 2-oxo-pyrrolidine ring in position 5 (1% of dose). There is no enantiomeric interconversion of levetiracetam or its major metabolite.

Elimination — Levetiracetam plasma half-life in adults is 7 ± 1 hour and is unaffected by either dose, route of administration or repeated administration. Levetiracetam is eliminated from the systemic circulation by renal excretion as unchanged drug which represents 66% of administered dose. The total body clearance is 0.96 mL/min/kg and the renal clearance is 0.6 mL/min/kg. The mechanism of excretion is glomerular filtration with subsequent partial tubular reabsorption. The metabolite ucb L057 is excreted by glomerular filtration and active tubular secretion with a renal clearance of 4 mL/min/kg. Levetiracetam elimination is correlated to creatinine clearance. Levetiracetam clearance is reduced in patients with renal impairment [see Dosage and Administration (2.6)and Use in Specific Populations (8.6)].

Elderly — Pharmacokinetics of levetiracetam were evaluated in 16 elderly subjects (age 61 to 88 years) with creatinine clearance ranging from 30 to 74 mL/min. Following oral administration of twice-daily dosing for 10 days, total body clearance decreased by 38% and the half-life was 2.5 hours longer in the elderly compared to healthy adults. This is most likely due to the decrease in renal function in these subjects.

Selected passages from the cited U.S. prescribing label. The studies concern the source product and populations named in each passage; they do not establish Walter-product bioequivalence, an approved indication, or the kinetics of another fixed combination. Tables and the full prescribing information remain available in the source.

Source: DailyMed: Levetiracetam — injection

Reference accessed . Label revision: 2026-08-03.

Manufacturing & packaging brief

Plan the liquid-injectable presentation.

Use this preparation guide for Levetiracetam 100 mg Liquid injectables. These are the decisions to resolve with the technical team before a site, process and commercial scope are confirmed.

Presentation & formulation

Confirm concentration, fill volume, route and whether the proposed container is single-dose or multidose. Identify the formulation and transfer information available.

Quality & technical transfer

Ask for review of the sterile-process strategy, applicable sterility, endotoxin and particulate controls, analytical methods and container-closure integrity requirements.

Review the technical documents

Packaging configuration

Specify ampoule, vial or other proposed container, contact materials, closure and secondary pack. Confirm equipment and facility fit for that configuration.

Explore packaging options

Details to confirm for this record

Concentration and pack size
The record does not state a complete concentration basis. Confirm the amount per volume or weight before a specification, label or quotation is finalised; no denominator has been assumed here.

Quantities, MOQ & lead time

For Levetiracetam 100 mg Liquid injectables, state the container count and fill volume, target market and reorder forecast. MOQ and lead time depend on the assessed formula, process, components, testing and project readiness; request those terms in writing.

Discuss this manufacturing brief

Explore the context

Build the right manufacturing brief.

Common questions

Before you request a quotation.

Levetiracetam 100 mg Liquid injectables

What is listed in the catalogue?

The catalogue lists Levetiracetam 100 mg as liquid injectables in its neurology & psychiatry navigation area and non-beta-lactam manufacturing stream.

How do you confirm manufacturing availability?

Send Walter your requirement for Levetiracetam 100 mg Liquid injectables. The team reviews the applicable product permission and unit, formulation and equipment fit, testing, packaging and production schedule before confirming the manufacturing scope in writing. Request the relevant product and facility documents with your enquiry.

What do I need for a quotation?

Share the exact composition and strength, liquid injectables presentation, target market, initial quantity, preferred pack and timing. Identify whether this is a new product, development brief or transfer.

The quotation must confirm MOQ, inclusions, prerequisites and lead time for the proposed product and site.

What is needed for Indian and export markets?

For India, share the intended brand or institutional supply requirement, pack sizes, initial order quantity and artwork needs for Levetiracetam 100 mg Liquid injectables. Confirm the applicable product permission, manufacturing unit and labelling requirements with the team.

For export, identify each destination country, proposed pack, language and registration or dossier requirements. Ask which product-specific quality and stability documents are available. Container compatibility and destination-market requirements need review; a catalogue record does not establish export registration or a shelf-life commitment.

How do I submit my enquiry?

Use the product-specific enquiry button to carry this composition and dosage form into the form. After a successful submission, a receipt reference confirms that your brief has been saved for review. Use the RFQ checklist to prepare the remaining details.

Technical document review

Which documents can I ask Walter to review?

Ask about manufacturing and packing records, specifications, analytical methods, Certificates of Analysis (COA), stability evidence, the Process Validation Protocol (PVP) and Process Validation Report (PVR). The wider checklist below covers supplier qualification, technical transfer and ongoing supply.

View the full document checklist 14 review areas
Site, licence and audit scope
Manufacturing licence, applicable product permissions, GMP certificates, Site Master File, supplier-qualification questionnaire and relevant audit responses.
Manufacturing, packing and batch release
Master Formula Record (MFR), master packing instructions, Batch Manufacturing Record (BMR), Batch Packing Record (BPR), reconciliation and authorised release records.
Process validation and continued verification
Process Validation Protocol (PVP), Process Validation Report (PVR), process performance qualification documents and continued process verification trends.
Equipment, facilities and utilities
Validation Master Plan (VMP), user requirements, DQ/IQ/OQ/PQ records, calibration and maintenance evidence for relevant equipment and utilities.
Cleaning, carryover and hold times
Cleaning Validation Protocol (CVP), Cleaning Validation Report (CVR), residue limits, recovery studies and applicable clean, dirty and process hold-time studies.
Specifications and analytical evidence
Specifications, Method of Analysis (MOA), Standard Testing Procedure (STP), Certificates of Analysis (COA), analytical validation, verification and method-transfer records.
Stability, packaging and transport
Stability protocols/reports, ongoing stability commitments, pack specifications, approved artwork, compatibility and applicable packaging or transport studies.
Development and technology transfer
Development report, technology-transfer protocol/report, gap assessment, control strategy, critical quality attributes and critical process parameters.
Quality reviews, investigations and changes
Product Quality Review (PQR) / Annual Product Review (APR), deviations, CAPA, change control, OOS/OOT trends, complaints, recalls and relevant SOP/training records.
Material suppliers and impurity risks
API/excipient supplier qualification, traceability, material COAs, relevant origin declarations and impurity risk assessments with supporting tests.
Sterile-product evidence, where applicable
Contamination Control Strategy (CCS), media-fill/aseptic simulation reports, sterilisation and filtration validation, environmental monitoring, sterility/endotoxin and container-closure integrity evidence.
Computerised systems and data integrity
Computerised-system validation, access controls, audit-trail review, backup/restore checks and relevant data-integrity procedures.
Market-specific regulatory support
Applicable dossier sections, API master-file/CEP support, bioequivalence or biowaiver evidence and Certificate of a Pharmaceutical Product (CPP/CoPP), where required and available.
Quality agreement and access arrangements
Quality/technical agreement covering responsibilities, release, changes, subcontracting, investigations, complaints, recalls, audits and document access.

Agree the list for the exact product, site, process, pack, market and project stage. QA confirms what exists, applies and may be shared; some records may require an NDA, redaction or controlled review. See document definitions and review guidance.

Important qualification

This B2B catalogue record is not proof of current approval or confirmation that Levetiracetam 100 mg Liquid injectables is available for sale. It is not prescribing information or patient advice. Any Drugs Rules status, current approval, exemption, applicable unit, licence scope, formulation, claims, brand use, destination-market registration and commercial feasibility require documentary verification and Walter's written confirmation. Read the full regulatory disclaimer.

Composition and classification are taken from Walter's product catalogue. The manufacturing guide helps buyers prepare a technical brief. Clinical references, where shown, describe the cited product and study. Manufacturing guide updated .